Katanax.Asia

CLICK HERE TO CONTACT US NOW: info@katanax.asia

 

 

The X-300 fluxer: What it does

Katanax X-300 Fluxer

Watch the video

The X-300 fluxer is the new reference for electric fusion in today's complex, busy lab environment.

Thanks to a clever electric furnace design, this unit can be ordered as a 1, 2 or 3 position fluxer, which can be expanded up to 3 positions at a later time, in the field. Indeed, everything is pre-wired for 3 positions, so increasing capacity is just a matter of adding mechanical components and re-configuring the furnace insulation walls. Borrowing the robust concept of its bigger brother (the six-position X-600), the X-300 also boasts revolutionary heating elements that are resistant to flux and chemical attacks. Heating elements can be changed individually, and will not become brittle.

The furnace heats up to the required temperature in less than 15 minutes in the morning, and will then remain ready for quick startup of a new batch of XRF beads or ICP solutions (with optional solution stirrer module). Automatic active power monitoring in the furnace achieves extraordinary temperature stability from one run to the next, and across all crucibles in the furnace.

The X-300 is pre-loaded with various fusion methods that can be used as is, or can be customized. All fusion methods can be saved, renamed, deleted or copied, just like computer files. Only the preset methods are protected to avoid accidental overwriting.

Upon turning the instrument on, the furnace door opens, the platinumware holders move forward and out of the furnace, and the door closes.

Up to three (3) platinum crucibles are loaded with a few grams of powdered sample, an appropriate flux and often other agents. The crucibles are inserted into the crucible holder.

Platinum molds are then installed onto the mold holder, and the safety shield can be closed. Since the platinumware holders are made of ceramics, there is no risk of contamination during the fusion.

When the user instructs the X-300 to launch the actual fusion, the safety shield locks, and then the oven door automatically opens, the platinumware holders enter the oven, the door closes and all heating steps are automatically started in sequence. Temperature is constantly monitored and displayed. An ambient LED lighting system switches to the color red.

The side-to-side rocking of the crucible holder continuously mixes the flux with the sample.

When the flux melts, it starts dissolving the sample. When all sample is dissolved, the oven door opens, the platinumware holders move forward and, during the time the door closes, the crucibles are tilted to the right to empty their contents into the molds.

Blowers located underneath cool the molds, while the oven remains powered, to gain time in the next cycle. When the molds are completely cooled, the ambient LED lighting system changes from red to blue, and the user is informed that he or she can now pick up perfectly homogenous glass beads, ready for analysis by XRF.

For solution preparation, the hot melt is poured into unbreakable beakers (instead of molds), which contains an acid stirred by an optional magnetic system.

 

 

CLICK HERE TO CONTACT US NOW: info@katanax.asia

 

 

 

The X-600 fluxer: What it does

Katanax X-600 Fluxer

Watch the video

The X-600 fluxer is the new reference for electric fusion in today's rugged, busy lab environment. Downtime is dramatically reduced, thanks to its revolutionary heating elements that are resistant to flux and chemical attacks. Heating elements can be changed individually, and will not become brittle.

The furnace heats up to the required temperature in less than 15 minutes in the morning, and will then remain ready for quick startup of a new batch of XRF beads or ICP solutions. Automatic active power monitoring in the furnace achieves extraordinary temperature stability from one run to the next, and across all crucibles in the furnace.

The X-600 is pre-loaded with various fusion methods that can be used as is, or can be customized. All fusion methods can be saved, renamed, deleted or copied, just like computer files. Only the preset methods are protected to avoid accidental overwriting.

Upon turning the instrument on, the furnace door opens, the platinumware holders move forward and out of the furnace, and the door closes.

Up to six (6) platinum crucibles are loaded with a few grams of powdered sample, an appropriate flux and often other agents. The crucibles are inserted into the crucible holder.

Platinum molds are then installed onto the mold holder, and the safety shield can be closed. Since the platinumware holders are made of ceramics, there is no risk of contamination during the fusion.

When the user instructs the X-600 to launch the actual fusion, the safety shield locks, and then the oven door automatically opens, the platinumware holders enter the oven, the door closes and all heating steps are automatically started in sequence. Temperature is constantly monitored and displayed. An ambient LED lighting system switches to the color red.

The back-and-forth rocking of the crucible holder continuously mixes the flux with the sample.

When the flux melts, it starts dissolving the sample. When all sample is dissolved, the oven door opens, the platinumware holders move forward and, during the time the door closes, the crucibles are tilted forward to empty their contents into the molds.

Twin blowers located underneath cool the molds, while the oven remains powered, to gain time. When the molds are completely cooled, the ambient LED lighting system changes from red to blue, and the user is informed to pick up perfectly homogenous glass beads, ready for analysis by XRF.

For solution preparation, the hot melt is poured into unbreakable beakers (instead of molds), which contains an acid stirred by an optional magnetic system.

 

CLICK HERE TO CONTACT US NOW: info@katanax.asia

 

Katanax Asia, is Experienced Agent of, Katanax, Automatic Fusion Machine, Sample Preparation for XRF, AA, ICP, Glass Beads, Flux, Lithium Tetraborate, Lithium Metaborate, Lithium Bromide, Lithium Carbonate, LiT, LiM, LiBr, 1222, 6634, 12-22, 66-34, Platinum Crucible, Mould, Platnium/Gold, Pt/Au, Pt95/Au5, Pt95%/Au5%, Platinum Refine, Platinum Scrap, Pt Scrap, Platinum Exchange, Buy back Scrap, XRF, Fluxer, Electrical Fluxer, Automatic Fluxer, Katanax.Asia, Katanax Thailand, Katanax Laos, Katanax Vietnam, Katanax Cambodia, Katanax Myanmar, Katanax Indochina, X-300, X-600, K-1, K1, K-1 Prime, K1-Prime, K1 Prime, K-1, K2, K-2 Prime, K2-Prime, K2 Prime, Katanax Spare Parts, Katanax Service Plan, Katanax Repair, Katanax Commissioning, Katanax On-site,Katanax onsite, Katanax Demonstration, Katanax Installation, Katanax Expert, Purchase Katanax, Buy Katanax, Katanax Specification, Katanax Fluxer

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

BELOW LISTED ARE OUR OLD MODELS: Discontinued but we are still offering life time support. Contact us now to get support: info@katanax.asia

 

The K1 Prime fluxer: What it does

Katanax K1 Prime Fluxer

Watch the video

The K1 Prime is pre-loaded with various fusion methods that can be used as is, or can be customized. All fusion methods can be saved, renamed, deleted or copied, just like computer files. Only the preset methods are protected to avoid accidental overwriting.

A standard platinum crucible is loaded with a few grams of powdered sample, an appropriate flux and often other agents. The crucible is inserted into the crucible heater, and locked by the heat reflector.

A platinum mold in a special holder is then installed in the mold heater.

When the user instructs the K1 Prime to launch the fusion, electricity heats the crucible element, and all heating steps are automatically started in sequence. Temperature is constantly monitored and displayed.

The tilting motion of the crucible heater continuously mixes the flux with the sample.

When the flux melts, it starts dissolving the sample. The mold heater element is then powered to prepare for pouring. When all sample is dissolved, the crucible holder tilts forward 130 from horizontal, to empty the crucible into the mold.

A fan located underneath cools the mold, while the crucible is ready to start a fusion again, to gain time. When the mold is completely cooled, the user picks a perfectly homogenous glass bead, ready for analysis by XRF.

For solution preparation, the hot melt is poured in an unbreakable beaker (instead of a mold), which contains an acid stirred by an optional magnetic system.

CLICK HERE TO CONTACT US NOW: info@katanax.asia

 

 

 

 

The K2 Prime fluxer: What it does

Katanax K2 Prime Fluxer

Watch the video

The K2 Prime is pre-loaded with various fusion methods that can be used as is, or can be customized. All fusion methods can be saved, renamed, deleted or copied, just like computer files. Only the preset methods are protected to avoid accidental overwriting.

Upon turning the instrument on, the furnace door opens, the platinumware holders move forward and out of the furnace, and the door closes. The heater then automatically reaches the user-preset holding temperature and is ready to fuse about 15 minutes after being turned on.

Up to six (6) platinum crucibles are loaded with a few grams of powdered sample, an appropriate flux and often other agents. The crucibles are inserted into the crucible holders.

Platinum molds are then installed onto the mold holder.

When the user instructs the K2 Prime to launch the actual fusion, the oven door automatically opens, the platinumware holders enter the oven, the door closes and all heating steps are automatically started in sequence. Temperature is constantly monitored and displayed.

The back-and-forth rocking of the crucible holder continuously mixes the flux with the sample.

When the flux melts, it starts dissolving the sample. When all sample is dissolved, the oven door opens, the platinumware holders move forward and, during the time the door closes, the crucibles are tilted forward to empty their contents into the molds.

Fans located underneath cool the molds, while the oven remains powered, to gain time. When the molds are completely cooled, the user picks up perfectly homogenous glass beads, ready for analysis by XRF.

For solution preparation, the hot melt is poured into unbreakable beakers (instead of molds), which contains an acid stirred by an optional magnetic system.

 

CLICK HERE TO CONTACT US NOW: info@katanax.asia